EXPERIMENTAL INVESTIGATION ON THE IMPACT OF CONCRETE STRENGTH ON THE DUCTILITY OF REINFORCED CONCRETE FRAME STRUCTURES

dc.contributor.authorGolam Kibria, Lieutenant Colonel Bhuiyan Mohammad
dc.date.accessioned2020-06-10T04:13:15Z
dc.date.available2020-06-10T04:13:15Z
dc.date.issued2019-12
dc.description.abstractThis experiment was undertaken to study the impact of concrete strength on the ductility of reinforced concrete frame structure. Two half scale interior joint with monolithic transverse beams and slab from a six storied residential building were selected for the experiment. The joints were constructed without any shear reinforcement within the joint region to evaluate the contribution of concrete strength in bond stress between the longitudinal reinforcement and concrete. Bond stress has important specific roles on the ductility of the joint in particular and on the ductility of the global structure in general. The models were subjected to incremental static cyclic lateral loading provided by hydraulic jacks under constant axial loading. Deflections and rotations were measured by dial gauges and a video extensometer. It is found from the study that ductility of the structural members i.e. beams, columns and joints increased remarkably with increased concrete strength.
dc.identifier.otherhttps://dspace.mist.ac.bd/server/api/core/items/7e57fe5c-dfae-499a-8cce-b690cdb40abc
dc.identifier.urihttp://hdl.handle.net/123456789/501
dc.language.isoen
dc.publisherR&D Wing, MIST
dc.sourceMIST Digital Archive
dc.subjectConcrete strength, ductility, interior joint, seismic loading
dc.titleEXPERIMENTAL INVESTIGATION ON THE IMPACT OF CONCRETE STRENGTH ON THE DUCTILITY OF REINFORCED CONCRETE FRAME STRUCTURES
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
140-_ Article Text (File_ docx with no Author Information)-238-1-10-20191216.pdf
Size:
416.54 KB
Format:
Adobe Portable Document Format