Experimental Investigation on Traditional Fan Performance Improvement using Front Mounted Cooling Coil of Vapor Compression Refrigeration System
| dc.contributor.author | Hridoy, Monowar Wadud | |
| dc.contributor.author | Mohammad, Mahathir | |
| dc.contributor.author | Islam, Saiful | |
| dc.contributor.author | Hakim, Md. Masbah-Ul | |
| dc.contributor.author | Kadir, C.H.M Imran | |
| dc.date.accessioned | 2026-07-06T19:36:34Z | |
| dc.date.available | 2026-07-06T19:36:34Z | |
| dc.date.issued | 19-Dec-2020 | |
| dc.description.abstract | The temperature of the world is increasing day by day and the effects of this warming are influential in Bangladesh. A | |
| dc.description.abstract | record amount of temperature is rising every year. So, in this situation to work and live comfortably in the hot summer | |
| dc.description.abstract | season it is necessary to have cooling devices. In Bangladesh, for the cooling purpose, most of the peoples generally use a | |
| dc.description.abstract | traditional fan. Only a few of them are capable to buy Air Conditioner because a major portion of its peoples is poor. But | |
| dc.description.abstract | only a fan sometimes is not enough to cool. So, the problem remains between cost and comfort. Considering this issue, a | |
| dc.description.abstract | solution is proposed in this work which may serve both the problems. The problem could be solved if a cooling coil is | |
| dc.description.abstract | placed on the path of air flow. When the incoming air is passed through the cooling coil it gets cool. The cooling coil is | |
| dc.description.abstract | activated by the Vapor compression refrigeration Cycle. This system also made portable. That is, one may call this system a | |
| dc.description.abstract | portable air cooler. For this cooling coil 50 feet, a copper tube is used. A 320-watt compressor and fin type condenser are | |
| dc.description.abstract | used to construct the vapor compression system. This cooling is used for spot cooling for a periodic basis. A 3.5ºC | |
| dc.description.abstract | temperature reduction has been found where the inlet and outlet temperature of the air is 25ºC and 21.5ºC respectively. | |
| dc.identifier.other | http://103.99.128.19:8080/jspui/handle/123456789/396 | |
| dc.identifier.uri | http://103.99.128.19:8080/xmlui/handle/123456789/396 | |
| dc.publisher | Department of Mechanical Engineering, KUET | |
| dc.source | CUET Digital Repository | |
| dc.subject | Cooling Coil | |
| dc.subject | Traditional fan | |
| dc.subject | Air conditioner | |
| dc.subject | Cost and Comfort | |
| dc.title | Experimental Investigation on Traditional Fan Performance Improvement using Front Mounted Cooling Coil of Vapor Compression Refrigeration System | |
| dc.title.alternative | 6th International Conference on Mechanical, Industrial and Energy Engineering 2020 | |
| dc.title.alternative | ICMIEE 2020 |