Flexible Screen-Printed Amperometric Sensors Functionalized With Spray-Coated Carbon Nanotubes and Electrodeposited Cu Nanoclusters for Nitrate Detection
| dc.contributor.author | Inam, A K M Sarwar | |
| dc.contributor.author | Angeli, Martina Aurora Costa | |
| dc.contributor.author | Shkodra, Bajramshahe | |
| dc.contributor.author | Douaki, Ali | |
| dc.contributor.author | Avancini, Enrico | |
| dc.contributor.author | Magagnin, Luca | |
| dc.contributor.author | Petti, Luisa | |
| dc.contributor.author | Lugli, Paolo | |
| dc.date.accessioned | 2024-05-30T06:06:09Z | |
| dc.date.available | 2024-05-30T06:06:09Z | |
| dc.date.issued | 2023-10-15 | |
| dc.description.abstract | In this work, we present a novel, sensitive, easy-to-fabricate, flexible amperometric sensor constituted by screen-printed silver (Ag) electrodes functionalized with a copper (Cu) film electrodeposited on top of a spray coated network of single-walled carbon nanotubes (SWCNTs). The Cu/SWCNTs/Ag electrode showed excellent catalytic activity towards the electro-reduction of nitrate ions at neutral pHwith a significant increasein cathodicpeak currents incomparison with the electrode without SWCNTs (Cu/Ag). The developed Cu/SWCNTs/Ag sensor showed a wide linear detection range from 0.5 μM to 6.0 mM (0.31 mg/l to 372.02 mg/l) with good sensitivity (18.39 μ A/mM) and a calculated limit of detection (LOD) of 0.166 nM(10.29 μ g/l). It also showed a good selectivity (maximum standard deviation (SD) was 3.25 μ A) towards different interfering ions (Fe2+, Na+, Cu2+, SO2−4, CH3COO−, Cl−, NO−2 and HCO−3), as well as good reproducibility,mechanical durability, time and temperature stability. In real sample analysis (tap and river water), the sensor exhibited good agreement with the compared outcome of high-performance liquid chromatography (HPLC) measurements, proving to be a promising analytical tool for the detection of nitrate in water. | |
| dc.identifier.other | http://dspace.daffodilvarsity.edu.bd:8080/handle/123456789/12554 | |
| dc.identifier.uri | http://dspace.daffodilvarsity.edu.bd:8080/handle/123456789/12554 | |
| dc.language.iso | en_US | |
| dc.publisher | IEEE | |
| dc.source | DIU Institutional Repository | |
| dc.subject | Technology | |
| dc.subject | Chromatography | |
| dc.subject | Carbon nanotubes | |
| dc.title | Flexible Screen-Printed Amperometric Sensors Functionalized With Spray-Coated Carbon Nanotubes and Electrodeposited Cu Nanoclusters for Nitrate Detection | |
| dc.type | Article |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Flexible_screen-printed_amperometric_sensors_funct.pdf.txt
- Size:
- 52.97 KB
- Format:
- Adobe Portable Document Format