Comparing the performance of different ultrasonic images enhancement for speckle noise reduction in ultrasound images using techniques: a preference study

No Thumbnail Available

Date

2017-06-19

Journal Title

Journal ISSN

Volume Title

Publisher

SPIE Digital Library

Abstract

Diagnostic ultrasound (US) is an important tool in today's sophisticated medical diagnostics. Nearly every medical discipline benefits itself from this relatively inexpensive method that provides a view of the inner organs of the human body without exposing the patient to any harmful radiations. Medical diagnostic images are usually corrupted by noise during their acquisition and most of the noise is speckle noise. To solve this problem, instead of using adaptive filters which are widely used, No-Local Means based filters have been used to de-noise the images. Ultrasound images of four organs such as Abdomen, Ortho, Liver, Kidney, Brest and Prostrate of a Human body have been used and applied comparative analysis study to find out the output. These images were taken from Siemens SONOLINE G60 S System and the output was compared by matrices like SNR, RMSE, PSNR IMGQ and SSIM. The significance and compared results were shown in a tabular format. Full Text Link: https://doi.org/10.1117/12.2280277

Description

Keywords

Ultrasound images, Speckle noise, Adaptive filter, Nonlocal means based speckle filter