Development of Carbon Monoxide detecting device using MQ-7 sensor along with its statistical analysis

dc.contributor.advisorAzad, Dr. A. K.M. Abdul Malek
dc.contributor.authorFerdousi, Jahan Ara
dc.contributor.authorAnanto, Samiul Ehsan
dc.contributor.authorAhmed, Md. Naveed
dc.date.accessioned2014-09-10T09:06:41Z
dc.date.available2014-09-10T09:06:41Z
dc.date.issued2014-08
dc.descriptionCataloged from PDF version of thesis report.
dc.descriptionIncludes bibliographical references (pages 50-51).
dc.descriptionThis thesis report submitted in partial fulfillment of the requirement for the degree of Bachelor of Science in Electrical and Electronic Engineering, 2014.
dc.description.abstractWe are in the 21st century, and nowadays many of us are concerned about our surroundings and environment. Ever since the industrial evolution the greenhouse gases level increased. So does the concentration of carbon monoxide gas in the atmosphere. Carbon Monoxide gases are present in various workplace and its presence is more significant due to burning of hydrocarbons. Day-by-day, the concern regarding the level of Carbon Monoxide is also arising due to such increase in industrial growth. Such problems cannot be overlooked nowadays. There are many sensors developed and used for sensing the level of Carbon Monoxide in various hazardous places like coal mine, sewage, etc. In our thesis we have been working with one such sensor which is the MQ-7. This sensor is easily available and affordable in our country Bangladesh. MQ-7 is a highly sensitive sensor for the determination of the level of carbon monoxide via an optical filter. In our thesis we have completely analyzed the analog and digital output of this sensor with various materials which gives out various levels of Carbon Monoxide when burned. We have discussed the relationship between the concentrations of Carbon Monoxide with the analog voltage reading in order to calibrate the sensor and besides we have carried out some simulation to support our data. Details of our work will be discussed in the following chapters.
dc.identifier.otherID 10221071
dc.identifier.otherID 10221059
dc.identifier.otherID 10221040
dc.identifier.otherhttps://dspace.bracu.ac.bd/server/api/core/items/32cdc12b-6d88-449a-8df6-a47187a4977f
dc.identifier.urihttp://hdl.handle.net/10361/3590
dc.language.isoen
dc.publisherBRAC University
dc.sourceBRAC University Institutional Repository
dc.subjectElectrical and electronic engineering
dc.subjectCarbon Monoxide
dc.subjectMQ-7
dc.titleDevelopment of Carbon Monoxide detecting device using MQ-7 sensor along with its statistical analysis
dc.typeThesis

Files