Analysis of Micro-Strip Patch Sensor of Various Sizes and Parameters for Non-invasive Electrolyte Sensing

dc.contributor.authorMd Toushique, Fardeen
dc.contributor.authorSaikot, Shoeb Mahmud
dc.contributor.authorNizam, Talha Bin
dc.date.accessioned2023-01-04T06:28:42Z
dc.date.available2023-01-04T06:28:42Z
dc.date.issued2022-05-30
dc.descriptionSupervised by Prof. Dr. Md. Taslim Reza Department of Electrical and Electronic Engineering (EEE), Islamic University of Technology (IUT), Gazipur-1704, Bangladesh. This thesis is submitted in partial fulfillment of the requirements for the degree of Bachelor of Science in Electrical and Electronic Engineering, 2022
dc.description.abstractElectrolyte imbalance is a major health issue that can go unnoticed due to the lack of frequent testing. Most prevalent electrolyte monitoring measures require direct blood testing which is invasive in nature. Invasive monitoring measures are not only painful but also time-consuming. So non-invasive electrolyte monitoring is slowly gaining popularity. In this paper, non-invasive micro-strip patch antennas of different sizes and parameters have been analyzed. Micro-strip patch antennas of five different sizes and five different parameters have been analyzed for their sensitivity, linearity, and accuracy for a frequency range of 0.01GHz to 0.2GHz. Seven different concentrations of NaCl have been used for this analysis. Various research papers have found that there is a correlation between changing concentrations of NaCl and reflection coefficient S11 and resonant frequency. From this analysis, it has been observed that changing antenna size causes changes in antenna characteristics.
dc.identifier.otherhttps://repository.iutoic-dhaka.edu/server/api/core/items/250f8772-ced5-441a-96d7-3f36d9259ce2
dc.identifier.urihttp://hdl.handle.net/123456789/1628
dc.language.isoen
dc.publisherDepartment of Electrical and Electronic Engineering(EEE), Islamic University of Technology(IUT),
dc.sourceIUT Institutional Repository
dc.subjectMPA, ISE, AAS, ECG, PCB, MBI, ISM, MICS, CPW, VWSR, CKD, OES, BP, LUTS, BOO, SCD, DC, IC, SNR
dc.titleAnalysis of Micro-Strip Patch Sensor of Various Sizes and Parameters for Non-invasive Electrolyte Sensing
dc.typeThesis