Thermoluminescence Dosimetry and Microstructural Characteristics of Gamma-Irradiated Natural Flake Graphite

dc.contributor.authorKhandaker, Mayeen Uddin
dc.contributor.authorLam, Siok Ee
dc.contributor.authorDaud, Amirul Najman Ariff Bin Md
dc.contributor.authorSani, Siti Fairus Abdul
dc.contributor.authorBradley, David Andrew
dc.contributor.authorAlzimami, Khalid S.
dc.contributor.authorAlmohammed, Huda I.
dc.contributor.authorHamd, Zuhal Y.
dc.contributor.authorOsman, Hamid
dc.date.accessioned2024-10-03T08:14:02Z
dc.date.available2024-10-03T08:14:02Z
dc.date.issued2024-08-15
dc.description.abstractThermoluminescence (TL) and microstructural analysis were conducted on natural flake graphite (NFG) to assess its suitability for radiotherapeutic x-ray dose measurements. The investigations encompassed the examination of TL glow curves, linearity, sensitivity, signal decay, and repeatability. NFG samples were exposed to 60Co gamma radiation doses ranging from 2 Gy to 20 Gy. The microstructure of the irradiated NFG was probed using a 532 nm laser Raman spectrometer. Promisingly, the NFG exhibited remarkable characteristics, including a moderately higher response to dose (R2 of about 96%), increased sensitivity at lower doses, and good repeatability (∼4%). Nevertheless, its fading rate reached about 80% after 14 days of irradiation. Additionally, the NFG intensity ratios of defect (D) to graphite (G), denoted as ID/IG, closely mirrored the oscillatory pattern observed in 50 μm thick graphite sheets and were approximately 1.6 times lower than those of similar graphite sheets with comparable carbon content (about 98% carbon). These findings suggest that NFG holds potential for the development of an affordable, non-hygroscopic, and tissue-equivalent TL dosimeter, with possible applications in the medical field.
dc.identifier.otherhttp://dspace.daffodilvarsity.edu.bd:8080/handle/123456789/13512
dc.identifier.urihttp://dspace.daffodilvarsity.edu.bd:8080/handle/123456789/13512
dc.language.isoen_US
dc.publisherElsevier
dc.sourceDIU Institutional Repository
dc.subjectRadiology
dc.subjectRadiotherapy
dc.titleThermoluminescence Dosimetry and Microstructural Characteristics of Gamma-Irradiated Natural Flake Graphite
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Thermoluminescence Dosimetry and Microstructural Characteristics of Gamma-Irradiated Natural Flake Graphite.docx
Size:
13.67 KB
Format:
Adobe Portable Document Format

Collections