Browsing by Author "Muslima, Umme"
Now showing 1 - 7 of 7
- Results Per Page
- Sort Options
Item Corrigendum to “investigation of Structural and Tl Kinetic Parameters of Smartphone Screen Protector Glasses for Applications in Retrospective Dosimetry”(Elsevier, 2024-09-02) Muslima, Umme; Khandaker, Mayeen Uddin; Nawi, S.N. Mat; Lam, S.E.; Sani, S.F. Abdul; Bradley, D.A.; Saidur, R.; Tan, Y.S.; Osman, Hamid; Hanfi, Mohamed Y.; Issa, Shams A.M.Item Exploring the thermoluminescence characteristics of smartphone screen safety glasses for retrospective dosimetry applications(2024-10-24) Muslima, Umme; Khandaker, Mayeen Uddin; Lam, S.E.; Nawi, S.N. Mat; Abdul Sani, S.F.; Ung, N.M.; Osman, Hamid; Y. Hanfi, Mohamed; Sayyed, M.I.; Alzimami, Khalid; Alqahtani, Amal; Bradley, D.A.In clinical settings, standard dosimeters might miss radiation mishaps. Retrospective dosimeters could help to track personnel (such as patients and other staff who don't wear dosimeters) exceeding safe limits and assess long-term exposure trends. This study has investigated key thermoluminescence (TL) dosimetric characteristics, including the glow curve structure, dose-response, energy dependence, sensitivity and fading of various safety glasses that are used as screen protectors of smartphones subjected to photon irradiation. Among the studied glasses, the HD Anti-Peep safety glass for iPhone has been found to exhibit a linear dose-response with a regression coefficient of 99% within the dose range of 2–10 Gy. Moreover, all the safety glasses showed independence with respect to photon energy of 6 MV and 10 MV. The TL glow curves of the samples showed a broad glow peak between 125 °C and 325 °C at 10 Gy. The TL kinetic parameters of the safety glasses were also studied by analyzing the glow curves using the peak shape and initial rise method. The geometric factor (μg) is found to be within the range of 0.43–0.53, which indicates the suitability of applying Chen's general-order formula to calculate the kinetic parameters such as activation energy, frequency factor and trap lifetime. The activation energy (E) and frequency factor (s) are found in the range of 0.31–0.54 eV and 4.55 × 103 to 2.12 × 106 s−1 respectively obtained via the peak shape method. The relatively long trap lifetime and observed thermoluminescence features indicate that the HD Anti-Peep safety glass offers a better option to estimate dose retrospectively to ensure the safety of human health.Item Exploring the Thermoluminescence Characteristics of Smartphone Screen Safety Glasses for Retrospective Dosimetry Applications(Elsevier, 2024-10-15) Muslima, Umme; Khandaker, Mayeen Uddin; Lam, S.E.; Mat Nawi, S.N.; Sani, S.F. Abdul; Ung, N.M.; Osman, Hamid; Hanfi, Mohamed Y.; Sayyed, M.I.; Alzimami, Khalid; Alqahtani, Amal; Bradley, D.A.In clinical settings, standard dosimeters might miss radiation mishaps. Retrospective dosimeters could help to track personnel (such as patients and other staff who don't wear dosimeters) exceeding safe limits and assess long-term exposure trends. This study has investigated key thermoluminescence (TL) dosimetric characteristics, including the glow curve structure, dose-response, energy dependence, sensitivity and fading of various safety glasses that are used as screen protectors of smartphones subjected to photon irradiation. Among the studied glasses, the HD Anti-Peep safety glass for iPhone has been found to exhibit a linear dose-response with a regression coefficient of 99% within the dose range of 2–10 Gy. Moreover, all the safety glasses showed independence with respect to photon energy of 6 MV and 10 MV. The TL glow curves of the samples showed a broad glow peak between 125 °C and 325 °C at 10 Gy. The TL kinetic parameters of the safety glasses were also studied by analyzing the glow curves using the peak shape and initial rise method. The geometric factor (μg) is found to be within the range of 0.43–0.53, which indicates the suitability of applying Chen's general-order formula to calculate the kinetic parameters such as activation energy, frequency factor and trap lifetime. The activation energy (E) and frequency factor (s) are found in the range of 0.31–0.54 eV and 4.55 × 103 to 2.12 × 106 s−1 respectively obtained via the peak shape method. The relatively long trap lifetime and observed thermoluminescence features indicate that the HD Anti-Peep safety glass offers a better option to estimate dose retrospectively to ensure the safety of human health.Item Investigation of structural and TL kinetic parameters of smartphone screen protector glasses for applications in retrospective dosimetry(2024-11-15) Muslima, Umme; Khandaker, Mayeen Uddin; Mat Nawi, S.N.; Lam, S.E.; Abdul Sani, S.F.; Bradley, D.A.; Saidur, R.; Tan, Y.S.; Osman, Hamid; Y. Hanfi, Mohamed; A.M. Issa, ShamsThe study evaluated the structural and thermoluminescence (TL) kinetic parameters of smartphone screen protector glasses in order to use them for post-accident dose reconstruction from unplanned nuclear events. The fact that most individuals use mobile phones in working environments including nuclear power plant sites, served as the impetus for the study. The TL glow curves indicate the physical properties of the defects involved in the luminescence process; therefore, they have been analyzed to study the TL kinetic parameters by employing peak shape, initial rise and glow curve deconvolution method within the dose ranges from 2 to 50 Gy. The geometric factor (μg) ranges between 0.46 and 0.56, suggesting that Chen's general-order method can be used to compute the kinetic parameters, including activation energy (E), frequency factor (s) and trap lifetime (τ). The examined trapping parameters (E = 0.33–0.57 eV, s = 5.22E+03–8.65E+06 s−1 for peak shape and E = 0.36–0.96 eV, s = 2.90E+04–1.88E+11 s−1 for initial rise methods) suggest promise for TL dosimetry applications. Additionally, the observed lifetime (τ = 4.88E+5 s) implies the feasibility of dose reconstruction even several days after an accident, making it suitable for retrospective dosimetry. Micro-Raman spectroscopy revealed a clear correlation between increasing gamma radiation dose and microstructural damage. The analysis of intensity ratio (ID/ISi) for other components to silica, along with the area of deconvoluted micro-Raman spectra in high-frequency regions, indicated dose-dependent structural modifications and internal defect annealing. Further confirmation of structural alterations within the studied dose range was obtained through the analysis of crystallite size (Lc), dislocation density (δ), lattice strain (ɛ) and FWHM (Full Width at Half Maximum) from XRD (X-ray diffraction) patterns. These findings collectively suggest the potential of smartphone screen protector glass as a viable material for emergency dosimetry applications.Item Synthesis, Characterization and Thermoluminescence Properties of LiCaPO4 Phosphor for Ionizing Radiation Dosimetry(Elsevier, 2023-12-15) Rahat, Md Raghib; Mimi, Homaira Afia; Islam, Shah Azharul; Kamruzzaman, Md.; Ferdous, Jannatul; Begum, Mahfuza; Hasnat, Md Abul; Abdul-Rashid, H.A.; Muslima, Umme; Khandaker, Mayeen Uddin; Bradley, D.A.; Al-Mamun, Md.; Rahman, A.K.M. MizanurMany minerals and compounds show thermoluminescence (TL) properties but only a few of them can meet the requirements of an ideal dosimeter. Several phosphate materials have been studied for low-dose dosimetryin recent times. Among the various phosphates, ABPO4-type material shows interesting TL properties. In this study, an ABPO4-type (A = Lithium, B=Calcium) phosphor is synthesized using a modified solid-state diffusion method. Temperature is maintained below 800 °C in every step of phosphor preparation to obtain the pure phase of Lithium calcium phosphate (LiCaPO4). The purpose of this work is to synthesize LiCaPO4 using a simple method, examine its structural and luminescence properties in order to gain a deeper understanding of its TL characteristics. The general TL properties, such as TL glow curve, dose linearity, sensitivity, and fading, are investigated. Additionally, this study aims to determine various kinetic parameters through Glow Curve Deconvolution (GCD) method using the Origin Lab software together with the Chen model. XRD analysis confirmed the phase purity of the phosphor with a rhombohedral structure. Lattice parameters, unit cell volume, grain size, dislocated density, and microstrain were also calculated from XRD data. Raman analysis and Fourier Transform Infrared analysis were used to collect information about molecular bonds, vibrations, identity, and structure of the phosphor. To investigate TL properties and associated kinetic parameters, the phosphor was irradiated with 6.0 MV (photon energy) and 6.0 MeV (electron energy) from a linear accelerator for doses ranging from 0.5 Gy to 6.0 Gy. For both photon and electron energy, TL glow curves have two identical peaks near 200 °C and 240 °C.The TL glow curves for 0.5 Gy–6 Gy are deconvoluted, then fitted with the appropriate model and then calculated the kinetic parameters. Kinetic parameters such as geometric factor (μg), order of kinetics, activation energy (E), and frequency factor (s) are obtained from Chen's peak shape method. The dose against the TL intensity curve shows that the response is almost linear in the investigated dose range. For photon and electron energy, the phosphor is found to be the most sensitive at 2.0 Gy and 4.0 Gy, respectively. The phosphor shows a low fading and after 28 days of exposure, it shows a signal loss of better than 3%. The studied TL properties suggest the suitability of LiCaPO4 in radiation dosimetry and associated fields.Item Tempered glass as a thermoluminescent medium for retrospective dosimetry(Scopus, 2024-04) Muslima, Umme; Khandaker, Mayeen Uddin; Lam, S.E.; Nawi, S.N. Mat; Sani, S.F. Abdul; Osman, Hamid; Hanfi, Mohamed Y.; Sayyed, M.I.; Bradley, D.A.Globally, the use of nuclear facilities and the potential risks associated with the dispersal of ionizing radiation due to natural disasters or technical failures are on the rise. These risks can have severe consequences for the environment and all living organisms, particularly humans. There is currently no practical method available to accurately estimate the radiation doses received by the surrounding areas and individuals in such situations. To address this issue, retrospective dosimetry can be employed to estimate the actual radiation dose, followed by the implementation of remediation techniques. Considering this need, tempered glass, which is commonly used as a screen protector for smartphones by the general public, has been identified as a promising medium for retrospective dosimetry. The present study aimed to investigate the thermoluminescence (TL) properties of six different types of tempered glass subjected to 60Co gamma rays, specifically examining the TL dose response, linearity, repeatability, and fading. Among the various glass samples tested, HD anti-peep tempered glass demonstrates a highly linear dose-response and the greatest dose sensitivity within the examined dose range of 2–50 Gy. Additionally, the HD anti-peep tempered glass exhibits minimal loss of TL yield (∼23%) at 28 days post-irradiation, making it particularly suitable for use as a retrospective dosimeter.Item Tempered Glass as a Thermoluminescent Medium for Retrospective Dosimetry(Elsevier, 2024-04-20) Muslima, Umme; Khandaker, Mayeen Uddin; Lam, S.E.; Nawi, S.N. Mat; Sani, S.F. Abdul; Osman, Hamid; Hanfi, Mohamed Y.; Sayyed, M.I.; Bradley, D.A.Globally, the use of nuclear facilities and the potential risks associated with the dispersal of ionizing radiation due to natural disasters or technical failures are on the rise. These risks can have severe consequences for the environment and all living organisms, particularly humans. There is currently no practical method available to accurately estimate the radiation doses received by the surrounding areas and individuals in such situations. To address this issue, retrospective dosimetry can be employed to estimate the actual radiation dose, followed by the implementation of remediation techniques. Considering this need, tempered glass, which is commonly used as a screen protector for smartphones by the general public, has been identified as a promising medium for retrospective dosimetry. The present study aimed to investigate the thermoluminescence (TL) properties of six different types of tempered glass subjected to 60Co gamma rays, specifically examining the TL dose response, linearity, repeatability, and fading. Among the various glass samples tested, HD anti-peep tempered glass demonstrates a highly linear dose-response and the greatest dose sensitivity within the examined dose range of 2–50 Gy. Additionally, the HD anti-peep tempered glass exhibits minimal loss of TL yield (∼23%) at 28 days post-irradiation, making it particularly suitable for use as a retrospective dosimeter.
